ISO 2592 Petroleum and related products -- Determination of flash and fire point

  • 信息来源:
  • 浏览次数:
  • 发布时间:2016-02-29 21:12:37

[导读]:ISO 2592 Petroleum and related products -- Determination of flash and fire points -- Cleveland open cup method This International Standard specifies a procedure for the determination of flash and fire points of petroleum products using the Cleveland open cup apparatus It is applicable to petroleum products having an open cup flash point above 79 °C, except fuel oils, which are most commonly tested by the closed cup procedure described in ISO 2719

标签:
ISO2592
flashpoint
ISO 2592 Petroleum and related products -- Determination of flash and fire points -- Cleveland open cup method 
1 Scope
This International Standard specifies a procedure for the determination of flash and fire points of petroleum products using the Cleveland open cup apparatus. It is applicable to petroleum products having an open cup flash point above 79 °C, except fuel oils, which are most commonly tested by the closed cup procedure described in ISO 2719[1].
NOTE Flash point and fire point are indications of the ability of a substance to form a flammable mixture with air under controlled conditions, and then to support combustion. They are only two of a number of properties that may contribute towards the assessment of overall flammability and combustibility of a material.
2 Normative references
The following normative documents contain provisions which, through reference in this text, constitute provisions of this International Standard. For dated references, subsequent amendments to, or revisions of, any of these publications do not apply. However, parties to agreements based on this International Standard are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies. Members of ISO and IEC maintain registers of currently valid International Standards.
ISO 3170:1988, Petroleum liquids — Manual sampling.
ISO 3171:1988, Petroleum liquids — Automatic pipeline sampling.
3 Terms and definitions
For the purposes of this International Standard, the following terms and definitions apply.
3.1 flash point
lowest temperature of the test portion, corrected to a barometric pressure of 101,3 kPa, at which application of a test flame causes the vapour of the test portion to ignite and the flame to propagate across the surface of the liquid, under the specified conditions of test
3.2 fire point
lowest temperature of the test portion, corrected to a barometric pressure of 101,3 kPa, at which application of a test flame causes the vapour of the test portion to ignite and sustain burning for a minimum of 5 s under the specified conditions of test